Chapter 2 – Command Line Interface (CLI)
Command Line Interface and Application Examples for Multi-Tech Systems, Inc. IP Modules (S000368F) 28
Serial Commands – Setup
Command Syntax set serial [s0/s1] baud-rate <baud>
Description
Sets the serial baud rate.
Default Value
115200
Success
OK
Error 1. Too few arguments
“Usage: set serial s0/s1 baud-rate <baud>
Type ‘set serial s0/s1 baud-rate ?’ for more information”
2. Invalid baud-rate
“error: baud-rate range : [300,……]
Type ‘set serial s0/s1 baud-rate ?’ for more information”
Command Syntax set serial [s0/s1] buffer-datasize <0/d bytes>
Description
This command primarily buffers the data.
Default Value
0 – No buffering.
Success
OK
Error 1. Too few arguments
“Usage: set serial s0/s1 buffer-datasize <0/d bytes>
Type ‘set serial s0/s1 buffer-datasize ?’ for more information”
2. Multiple matches
buffer-datasize buffer-time
3. Datasize range
“error: Buffer data-size range : [1 - 1500] bytes
Type ‘set serial s0/s1 buffer-datasize ?’ for more information”