AT Commands for the MT5656ZDX, MT5600ZDX, MT5600BA/BL-Series Modems
34
Multi-Tech Systems, Inc. Commands Reference Guide (PN S000273D)
+MS= Modulation Selection Continued
<mod> Modulation Possible rates (bps)
1
0 V.21 300
1 V.22 1200
2 V.22bis 2400 or 1200
3 V.23 1200
9 V.32 9600 or 4800
10 V.32bis 14400, 12000, 9600, 7200, or 4800
11 V.34 33600, 31200, 28800, 26400, 24000, 21600, 19200,
16800, 14400, 12000, 9600, 7200, 4800, or 2400
12
2
V.90 56000, 54667, 53333, 52000, 50667, 49333, 48000,
46667, 45333, 44000, 42667, 41333, 40000, 38667,
37333, 36000, 34667, 33333, 32000, 30667, 29333, or
28000
56
3
K56flex 56000, 54000, 52000, 50000, 48000, 46000, 44000,
42000, 40000, 38000, 36000, 34000, 32000
64 Bell 103 300
69 Bell 212 1200
Table Notes:
1. See optional <automode>, <min_RX_rate>, <max_RX_rate>, and
<max_TX_rate> subparameters.
2. Selects V.90 modulation as first priority. If a V.90 connection cannot be
established, the modem attempts K56flex, V.34, V.32bis, etc. (Default)
3. Selects K56flex modulation as first priority. If a K56flex connection cannot
be established, the modem attempts V.90, V.34, V.32bis, etc.
automode An optional numeric value that enables or disables automatic
modulation negotiation using V.8 bis/V.8 or V.32 bis Annex A. The
options are:
0 = Disable automode
1 = Enable automode (default)
min_RX_rate An optional number that specifies the lowest rate at which
the modem may establish a receive connection. The value is decimal
coded in units of bps, e.g., 2400 specifies the lowest rate to be 2400
bps. See “Possible rates” in the mod table. The default is 300 for 300
bps.
max_RX_rate An optional number that specifies the highest rate at
which the modem may establish a receive connection. The value is deci-
mal coded in units of bps, e.g., 28800 specifies the highest rate to be
28800 bps. See “Possible rates” in the mod table. The default is 56000,
for 56000 bps.
x_law An optional number that specifies the PCM code type for 56K
modulation. The options are:
0 = µ-Law—used in North America and Japan (default)
1 = A-Law—used outside North America and Japan
The modem automatically selects A-Law or µ-Law if the server sends the
Conexant ID. Note that the ATZ command restores the x_law value from
NVRAM. You can also manually select A-Law or µ-Law using the %U
command.
reserved Must not be changed from the default value of 0.
max_TX_rate An optional number that specifies the highest rate at
which the modem may establish a transmit connection. The value is
decimal coded in units of bps, e.g., 33600 specifies the highest rate to
be 33600 bps. See “Possible rates” in the mod table. The default is
33600, for 33600 bps.