Strona 2 - P/N 82034802Rev.C

10MT64DSU Owner's ManualBack PanelThe cable connections for the MultiDSU64K are made at the backpanel. The input data (DCE interface) is through

Strona 3 - Contents

11Chapter 1 - Introduction and DescriptionFeaturesYour Multi-Tech DSU/CSU provides the following features:• supports direct connection to the DATAPHON

Strona 4 - Appendixes

12MT64DSU Owner's ManualTechnical Specifications• InterfacesRS-232C DB25S (female)V.35 34-pos. rectangular (female)DDS RJ48 8-position keyed jack

Strona 5

MultiDSU64KChapter 2 - Installation and Cabling

Strona 6

14MT64DSU Owner's ManualIntroductionThis chapter provides information for configuring and cabling theMultiDSU64K. It is assumed that the reader i

Strona 7 - About This Manual

15Chapter 2 - Installation and ConnectionCabling ProcedureInstallation of the MultiDSU64K includes making the proper cableconnections and turning powe

Strona 8 - CSU Functions

16MT64DSU Owner's ManualDIP Switch SettingsThe MultiDSU64K printed circuit board contains one 12-positionDIP-Switch block and one 4-position DIP-

Strona 9 - Front Panel Indicators

17Chapter 2 - Installation and ConnectionSwitches #1 and #2Speed Switches(Synchronous Mode)DIP-Switches #1 and #2 are used to set the synchronous data

Strona 10 - Back Panel

18MT64DSU Owner's ManualDDS clocking (default) allows the MultiDSU64K to accept timingsignals from the DDS network’s receive bipolar signal. Use

Strona 11 - Features

19Chapter 2 - Installation and ConnectionSwitch #7Data Set Ready "DSR"(Asynchronous/Synchronous Mode)When this option is enabled, the MultiD

Strona 12 - Technical Specifications

Owner’s Manual P/N 82034802Rev.C Model MT64DSUThis publication may not be reproduced, in whole or in part, without priorexpressed written permission f

Strona 13 - MultiDSU64K

20MT64DSU Owner's ManualElastic Store Enabled = Switch #12 UPElastic Store Disabled = Switch #12 DOWN(Factory Default Setting = DOWN)Switch #13Th

Strona 14 - Safety Warnings

MultiDSU64KChapter 3 - Testing

Strona 15 - Cabling Procedure

22MT64DSU Owner's ManualDiagnostic TestsThe MultiDSU64K is set to a default of Normal (non-diagnostic)mode at the factory.When a failure occurs i

Strona 16 - DIP Switch Settings

23Chapter 3 - TestingLocal Loopback TestThis test allows you to test the local DTE and the localMultiDSU64K. Use the following steps to perform the Lo

Strona 17 - External clocking

24MT64DSU Owner's ManualDigital Loopback TestThis test allows you to test the local DTE, the local MultiDSU64K,the communications link, and the r

Strona 18 - Carrier on

25Chapter 3 - TestingLocal Loopback Test With Test PatternThis test allows you to test the local MultiDSU64K.Perform the following steps to enable thi

Strona 19 - “drifts”

26MT64DSU Owner's ManualDigital Loopback Test With Test Pattern TestThis test allows you to test the local MultiDSU64K, thecommunications link, a

Strona 20

27Chapter 3 - TestingRemote Loopback TestThis test allows you to test the local DTE, the local MultiDSU64K,the communications link, and the remote Mul

Strona 21

28MT64DSU Owner's ManualRemote Loopback Test With Test Pattern TestThis test allows you to test the local MultiDSU64K, thecommunications link, an

Strona 22 - DSU Loopback Test

29Chapter 3 - TestingDSU Back-to-Back TestThis test lets you connect two DSUs with a back-to-back cable toverify proper DSU operation. Using a DSU tha

Strona 23 - Local Loopback Test

ContentsChapter 1 - Introduction and DescriptionIntroduction ... 6About T

Strona 24 - Digital Loopback Test

30MT64DSU Owner's Manual

Strona 25

MultiDSU64KChapter 4 - Warranty, Service andTech Support

Strona 26

32MT64DSU Owner's ManualIntroductionThis chapter starts out with statements about your MultiDSU64K'stwo-year warranty. The next section, Tec

Strona 27 - Remote Loopback Test

33Chapter 4 - Warranty, Services, and Tech SupportTech SupportMulti-Tech has an excellent staff of technical support personnelavailable to help you ge

Strona 28

34MT64DSU Owner's ManualServiceIf your tech support specialist decides that service is required, yourMultiDSU64K may be sent (freight prepaid) to

Strona 29 - DSU Back-to-Back Test

35Chapter 4 - Warranty, Services, and Tech SupportTo log on to the Multi-Tech BBS1. Set your communications program to 8-N-1.2. Dial our BBS at (800)

Strona 30 - MT64DSU Owner's Manual

36MT64DSU Owner's Manual2. Mark each file area you would like to examine by typing itslist number and pressing ENTER.3. Enter L to list all the f

Strona 31

37Chapter 4 - Warranty, Services, and Tech SupportAbout the Multi-Tech Fax-Back ServiceMulti-Tech’s fax-back system provides 24-hour access to sales,m

Strona 33 - Tech Support

MultiDSU64KAppendixes

Strona 34 - The Multi-Tech BBS

Chapter 4 - Warranty, Service andTech SupportIntroduction ... 32Limited War

Strona 35 - To Download a file

40MT64DSU Owner's ManualAppendix A - AT Commands and S-RegistersIntroductionAT commands are the means by which you, and your datacommsoftware, ar

Strona 36 - About the Internet

41AppendixesAction CommandsA/ Re-execute previous command (no AT prefix requiredwith this command).DSnDial a stored number (n = 0 thru 9 memory locati

Strona 37

42MT64DSU Owner's ManualS-RegistersCertain configurations are stored in memory registers called,S-Registers. The S command is used to assign a v

Strona 38

43AppendixesS4 DCE Interface ModeS4 = 0 DCE Interface is AsyncS4 = 1 DCE Interface is SyncS5 (Not Used)S6 (Not Used)S7 Echo Canceler ToneS7 = 0 Echo C

Strona 39

44MT64DSU Owner's ManualS15 Async DTE DialingS15 = 0 DisabledS15 = 1 DTR low-to-high TransitionS15 = 2 AT CommandS15 = 3 DTR or AT CommandS

Strona 40 - AT Commands

45AppendixesResult CodesWhen the MultiDSU64K receives an AT command from the terminalor PC, the MultiDSU64K tries to execute the command, then sendsa

Strona 41

46MT64DSU Owner's ManualConfiguration OptionsThis section describes the configuration parameters option settings.Corresponding S-Registers and AT

Strona 42 - S-Registers

47AppendixesDTE Dialing (S15) - Selects the type of asynchronous auto-dialingto be used by the DTE port. Options are AT Command, DTR (low-to-high), A

Strona 43

48MT64DSU Owner's ManualSynchronous Auto-DialThe beginning of this chapter described the AT command set whichenables the MultiDSU64K to dial, han

Strona 44 - S19 Parameter Lock

49AppendixesClear Number in Memory (CLA) CommandThe CLA command clears a specific number in the nn phonenumber memory location by entering CLAnn.Dial

Strona 45 - Result Codes

MultiDSU64KChapter 1 - Introduction and Description

Strona 46 - Configuration Options

50MT64DSU Owner's ManualV.25bis Result CodesV.25bis Responses (Result Codes)When in V.25bis mode, your MultiDSU64K provides you with severalrespo

Strona 47 - Parameter Options

51AppendixesAppendix B - Application ExamplesINTRODUCTIONThis section illustrates several types of applications in which theMultiDSU64K is typically u

Strona 48 - List of Commands

52MT64DSU Owner's ManualMultipoint DDS provides communication between a control stationand two or more remote stations. All data transmitted by t

Strona 49

53AppendixesLOCAL AREA DATA SET APPLICATIONYour MultiDSU64K can be used as a point-to-point LADS (LocalArea Data Set) at transmission speeds of 2400,

Strona 50 - V.25bis Result Codes

54MT64DSU Owner's ManualEXTERNAL CLOCKING APPLICATIONThis application is similar to the Local Area Data Set applicationexcept for the timing opti

Strona 51 - INTRODUCTION

55AppendixesThe analog modem at the same end as the MultiDSU64K must haveExternal Timing enabled; the modem at the end of the off-netextension must ha

Strona 52

56MT64DSU Owner's ManualAppendix C - Interface Signals and ConnectorPinoutsDDS RJ48S CONNECTORPin 1Pin 8KeyAs viewed from the rearFigure C-1. RJ4

Strona 53 - “cross-over”

57AppendixesRS-232C DB25S CONNECTORFigure C-2. RS-232 ConnectionDESCRIPTIONThis connector ties the MultiDSU64K to the DTE. The DB25Sconnector has the

Strona 54 - EXTERNAL CLOCKING APPLICATION

58MT64DSU Owner's ManualV.35 34-PIN CONNECTORCHMSWAAEEKKDJNTXBBFFLLAEKPUYCCHHMMBFLRVZDDJJNNV.35 34-PIN CONNECTORSignal Designation Signal Designa

Strona 55

59AppendixesLOOPBACK CABLE18 Figure C-4. Loopback CableDESCRIPTIONThis cable lets you test the MultiDSU64K when a second DSU is notavailable. It tests

Strona 56 - As viewed from the rear

6MT64DSU Owner's ManualIntroductionWelcome to Multi-Tech's new MultiDSU64K a stand-alone integratedData Service Unit (DSU), model number MT6

Strona 57

60MT64DSU Owner's ManualBACK-TO-BACK CABLE18Figure C-5. Back-to-Back CableDESCRIPTIONThis cable lets you test a suspect DSU by connecting it to a

Strona 58 - V.35 34-PIN CONNECTOR

61AppendixesCROSSOVER CABLE Modem(DCE) DSU (DCE)TxDRxDRTSCTSDSRGND CDDTR RI 2 3 4 5 6 7 82022 2 3 4 5 6 7 82022TxDRxDRTSCTSDSRGND CDDTR RIMaleMale

Strona 59 - “loops”

62MT64DSU Owner's ManualAppendix D - DIP-Switch SummarySynchronousDIP-Switch EffectSync Speeds9.6K 19.2K 56K 64K#1 DN UP *DN UP#2 DN DN *UP UPInt

Strona 60

63AppendixesAppendix E - FCC Regulations for Telephone LineInterconnection1. This equipment complies with Part 68 of the FederalCommunications Commiss

Strona 61

64MT64DSU Owner's Manual6. If trouble is experienced with this equipment (see modelindicated below) please contact Multi-Tech Systems, Inc. at th

Strona 62 - DIP-Switch Effect

65IndexIndexAAbout This Manual 7Action Commands 41ANALOG OFF-NET EXTENSIONAPPLICATION 54Analog Off-Net Extension Applica-tion 55Application Examples 5

Strona 63 - Interconnection

66MT64DSU Owner's ManualLLimited WarrantyOn-line Warranty Registration 32Listing Numbers Stored in Memory(RLN) Command 49Local Area DataA Set App

Strona 64

7Chapter 1 - Introduction and DescriptionAbout This ManualThis manual describes the MultiDSU64K and explains how to installand cable the unit. The inf

Strona 65

8MT64DSU Owner's ManualDSU Basic FunctionsA DSU (Data Service Unit) and a CSU (Channel Service Unit) aretypically connected to provide the interf

Strona 66

9Chapter 1 - Introduction and DescriptionFront Panel IndicatorsThe MultiDSU64K has seven diagnostic LED indicators. They are:DSU64KCTSCD RD SD Send