V.35 Shunt Procedure
7
V.35 Shunt Procedure
If you are using an external DCE device on the WAN 2 RS232/
V.35 port, and the connection will be a V.35 connection, the the
interal shunt must be moved from the RS232C (default)
position prior to cabling and power-up. The following steps
detail the procedures for switching the shunt.
Step Procedure
1 Ensure that the external power supply is disconnected
from the ProxyServer.
2 Turn the ProxyServer over and remove the cabinet
mounting screw from the chassis.
Front Panel
Back Panel
Cabinet Mounting Screw
Figure 2-2. Cabinet Mounting Screw
3 Being sure to support the back panel, turn the
ProxyServer right-side-up, tilt the back panel down, and
slide the circuit board out of the chassis.