Chapter 2 – Dialing Services
Multi-Tech Systems, Inc. AT Commands for Wireless Modems with IP Connectivity (S000333D) 8
#REDIALCOUNT Set Connection Attempts Allowed
Definition: This parameter indicates how many unsuccessful connection attempts the TCP/IP stack software will
make before terminating the connection attempt activity.
Values: Integer between 0 and 14, inclusive. Default 5.
If the value is set to 0, the TCP/IP stack software will not make any call retry.
Syntax: Set Value: AT#REDIALCOUNT=<value>
Get Value: AT#REDIALCOUNT? or AT#VPHY, AT#VALL
#REDIALDELAY Set Call Retry Delay
Definition: This parameter controls the delay (in seconds), if any, that will exist between each call retry.
Values: Integer between 5 and 14 inclusive. Default 5.
If this parameter is configured to zero, the TCP/IP stack software will attempt another connection
immediately after terminating the previous unsuccessful attempt.
Syntax: Set Value: AT#REDIALDELAY=<value>
Get Value: AT#REDIALDELAY? or AT#VPHY, AT#VALL
#PHYTIMEOUT Set Inactivity Time
Definition: This parameter is used by the TCP/IP stack software in order to terminate connections to the telephone
line when a long period elapses without activity. “Without activity” is defined as a period when no data
is transferred between the Internet and the TCP/IP stack software or between the TCP/IP stack
software and the attached equipment. This timer prevents the telephone line from being connected
indefinitely for any reason.
Note: When the inactivity timer expires, the modem ends the communication.
Values: Integer between 1 and 255 inclusive. This timer is set in minutes. Default 15.
Syntax: Set Value: AT#PHYTIMEOUT=<value>
Get Value: AT#PHYTIMEOUT? or AT#VPHY, AT#VALL
Return Codes: TIMEOUT: The inactivity timer is reached; the modem ends the communication.
#RINGCOUNT Set Number of Rings/Automatic Operation
Definition: This parameter defines the number of rings that will be counted before an automatic operation occurs
when receiving an incoming call.
It applies only when the ANSWERMODE parameter is set to an automatic mode (value>0).
If the ANSWERMODE parameter is used (value not 0), the RINGCOUNT value must also be >0.
Note: The RINGCOUNT parameter must be configured in accordance with the ATS0 configuration to
prevent conflicting interaction with the two features.
Values: Integer between 0 and 15 inclusive. Default 0.
Syntax: Set Value: AT#RINGCOUNT=<value>
Get Value: AT#RINGCOUNT? or AT#VPHY, AT#VALL
#DIALN1 Set Primary Dial-Up Number
Definition: This parameter is the primary dial-up phone number that will connect with the local ISP. Length
depends on country/region.
Values: Decimal phone numbers. No default.
Syntax: Set Value: AT#DIALN1=<value>
Get Value: AT#DIALN1? or AT#VPHY, AT#VALL
Komentarze do niniejszej Instrukcji